  Features: • UL, EN, IEC 60601-1 3.1 Edition Medical • 2 MOPP Protection • Universal Input 100 - 240 Vac • Single to Triple Output • IEC 320 C14 Input • Over-Voltage Protection • Over-Current Protection • 100% Burn-In • RoHS 2 (2011/65/EU) Compliant • Class I  
$0.00
Max:
Min: 1
Step: 1
  Features: • UL, EN, IEC 60601-1 3.1 Edition Medical • 2 MOPP Protection • Universal Input 100 - 240 Vac • 5 - 40 Vdc, Single Output • Internal EMI Filter • Over-Current Protection • Over-Voltage Protection • Short Circuit Protection • 100% Burn-In • RoHS 2 (2011/65/EU) Compliant • Class II  
$0.00
Max:
Min: 1
Step: 1
  Features: • UL, EN, IEC 60601-1 3.1 Edition Medical • 2 MOPP Protection • Universal Input 90 – 264 Vac • Single Output Voltage Available from 5 Vdc – 36 Vdc • Over-Voltage, Over-Current, and Short Circuit Protection • Internal EMI Filter • Input Surge Current Protection • Active Power Factor Correction • 100% Burn-In • RoHS 2 (2011/65/EU) Compliant • Class I  
$0.00
Max:
Min: 1
Step: 1
  • 20 – 30 Watts • 5 – 48 Vdc • C8, C18 Input Socket • UL, EN, IEC 60601-1 3.1 Edition • UR/cUR, TUV T-mark, CE, CB, PSE, FCC  
$0.00
Max:
Min: 1
Step: 1
  Features: • UL, EN, IEC 60601-1 3.1 Edition Medical • 2 MOPP Protection • Universal Input 100 – 240 Vac • IEC320-C6, C8 or C14 Input Socket • Output Voltage Available from 10 Vdc - 48 Vdc • Over-Current Protection, Over-Voltage Protection • 100% Burn-In • RoHS 2 (2011/65/EU) Compliant • Energy Efficiency Level: V  
$0.00
Max:
Min: 1
Step: 1
  Features: • UL, EN, IEC 60601-1 3.1 Edition Medical • 2 MOPP Protection • Universal Input 90 – 260 Vac • IEC320-C14 Input Socket • Output Voltage Available from 11 Vdc - 48 Vdc • Over-Current Protection • Over-Voltage Protection • 100% Burn-In • RoHS 2 (2011/65/EU) Compliant • Class I  
$0.00
Max:
Min: 1
Step: 1
  Features: • UL, EN, IEC 60601-1 3.1 Edition Medical • 2 MOPP Protection • Universal Input 100 - 240 Vac • 5 Vdc Standby Output • Internal EMI Filter • Convection Cooled • Over-Voltage, Over-Current, and Short Circuit Protection • Active Power Factor Correction • 100% Burn-In • RoHS 2 Compliant • 2 MOPP Protection • Class I  
$0.00
Max:
Min: 1
Step: 1
  Features: • UL, EN, IEC 60601-1 3.1 Edition Medical • 2 MOPP Protection • Universal Input 100 – 240 Vac • Convection Cooled • Single Output 12, 24 Vdc • Active Power Factor Correction • Input Surge Current Protection • Over-Current Protection • Over-Voltage Protection • RoHS 2 (2011/65/EU) Compliant • 100% Burn-In • Class I  
$0.00
Max:
Min: 1
Step: 1
  Features: • UL, EN, IEC 60601-1 3rd Edition Medical • 2 MOPP Protection • Universal Input 100 – 240 Vac • 9 Vdc to 15 Vdc • 15 to 36 Watts • Available in Wall Plug-in or Desktop Styles • High Efficiency, Low Cost Design • Over-Voltage Protection • Short Circuit Protection • RoHS 2 (2011/65/EU) Compliant • Energy Efficiency Level: V  
$0.00
Max:
Min: 1
Step: 1
  Features: • Universal Input 100 – 240 Vac • High Efficiency, Low Cost Design • 10 to 36 Watts • 5 Vdc to 48 Vdc • Available with U.S., European, British, Australian, China, and South Africa/India Input Plugs • Over-Voltage Protection • Short Circuit Protection • RoHS 2 (2011/65/EU) Compliant • Energy Efficiency Level: V & VI  